TM 1-1520-238-T-4
Change 8
682.19
621.2. HOD XMN 2 READING DISPLAYS HIGH OIL TEMPERATURE
621.2
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Personnel Required:
67R
Attack Helicopter Repairer
152FG
Maintenance Test Pilot
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R200 access panel open.
WARNING
Components may be hot enough to
cause burns. If injury occurs, seek
medical aid immediately.
1. Check other HOD oil temperature readings.
Are all readings relatively the same with
none >130 C?
YES
Readings are normal for
operating environment.
Go to paragraph 613.
NO
Go to step 2.
2. Check HOD XMN 2 oil pressure display.
Is pressure in normal range (55 85 LB)?
YES
Go to step 3.
NO
Go to paragraph 617.3.
3. Visually inspect XMN 2 oil system for low oil
level and damage (TM 1-1520-238-23).
Is damage present?
YES
Repair or replace damaged
component
(TM 1-1520-238-23).
Go to paragraph 613.
NO
Go to step 4.
4. Inspect XMN 2 oil heat exchanger for dirt or
blockage.
Is dirt or blockage present?
YES
Clean cooling fins
(TM 1-1520-238-23).
Go to paragraph 613.
NO
Replace XMN 2 oil temperature
transducer (MT13)
(TM 1-1520-238-23). Go to
paragraph 613.
END OF TASK