TM 1-1520-238-T-4
682.20
Change 5
622.
HOD NGB 2 READING DOES NOT DISPLAY AMBIENT TEMPERATURE
622
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
TM 55-1500-323-24
TM 9-1230-476-20-2
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R200 access panel and
RN6, R60 fairings open.
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
NOTE
Nose gearbox will display higher than
ambient temperature if recently
operated.
Entry in ( ) following pin locations is
multimeter lead orientation.
1. Detach P60. Check for open between:
P60F and P60G (red/blk),
P60J and P60H (blk/red).
Does open exist?
YES
Go to step 3.
NO
Go to step 2.
2. Check for short between:
P60F and ground,
P60G and ground,
P60H and ground,
P60J and ground.
Does short exist?
YES
Go to step 3.
NO
Go to step 4.
3. Locate open or short in wire harness between
P60 and MT16.
Can wire harness be repaired?
YES
Repair wiring
(TM 55-1500-323-24).
Go to paragraph 613.
NO
Replace MT16
(TM 1-1520-238-23).
Go to paragraph 613.
4. Detach P672. Check for short between:
P67286 and ground,
P67287 and ground.
Does short exist?
YES
Repair shorted wire between:
P67286 and ground,
P67287 and ground
(TM 55-1500-323-24).
NO
Go to step 5.
5. Reconnect P60. Check for open between:
P67286 and P67287 (blk/red).
Does open exist?
YES
Repair open wire
(TM 55-1500-323-24).
Go to paragraph 613.
NO
Refer to TM 9-1230-476-20-2 to
troubleshoot multiplex
subsystem.
END OF TASK