TM 1-1520-238-T-7
11277
1154.
CPG BUCS ON INDICATOR REMAINS LIGHTED
1154
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
References:
TM 1-1520-238-T-6
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check for short between P1940 and ground.
Does short exist?
YES
Go to step 2.
NO
Refer to TM 1-1520-238-T-6 to
troubleshoot CPG
caution/warning system.
2. Detach P18. Check for short between P1940
and ground.
Does short exist?
YES
Repair shorted wire between
P1940 and P18114.
Go to paragraph 1123.
NO
Refer to TM 1-1520-238-T-6 to
troubleshoot CPG
caution/warning system.
END OF TASK