TM 1-1520-238-T-7
11279
1155. CPG DIR LVDT NO-GO CPG COMPARTMENT APPEARS ON HOD (cont)
1155
7. (ACA) Attach P686. Check for 26 VAC at
P235A.
Is voltage present?
YES
Go to step 8.
NO
Go to step 11.
8. (ACA) Check for open between P235B and
P499B17.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Replace CPG directional (yaw)
LVDT (TM 1-1520-238-23).
9. (ACB) Attach P686. Check for 26 VAC at
J2351.
Is voltage present?
YES
Go to step 10.
NO
Go to step 12.
10. (ACB) Check for open between 2352 and
P6938.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Replace CPG directional (yaw)
LVDT (TM 1-1520-238-23).
11. (ACA) Check for open between P235A and
P499B16.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to paragraph 1176.
12. (ACB) Check for open between 2351 and
P6937.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to paragraph 1176.
END OF TASK