TM 1-1520-238-T-7
11278
1155. CPG DIR LVDT NO-GO CPG COMPARTMENT APPEARS ON HOD
1155
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Place CPG directional pedals to full right or full
left. Detach P686. Check for 10 VAC at
P68641.
Is voltage present?
YES
(ACA) Replace DASEC
(TM 1-1520-238-23).
(ACB) Go to step 2.
NO
(ACA) Go to step 3.
(ACB) Go to step 4.
2. (ACB) Attach P686. Detach filter adapter A707.
Check for 10 VAC at A70741.
Is voltage present?
YES
Replace DASEC
(TM 1-1520-238-23).
NO
Replace filter adapter
(TM 1-1520-238-23).
3. (ACA) Detach P686. Check for short between:
P235C and ground,
P235D and ground.
Does short exist?
YES
Repair shorted wire between:
P235D and J912B11,
P235C and J912B12,
P912B11 and J447B14,
P912B12 and J447B15,
P447B14 and P68641,
P447B15 and P68640.
Go to paragraph 1123.
NO
Go to step 5.
4. (ACB) Detach P686. Check for short between:
J2353 and ground,
J2354 and ground.
Does short exist?
YES
Repair shorted wire between:
J2354 and J912B11,
J2353 and J912B12,
P912B11 and J447B14,
P912B12 and J447B15
P447B14 and P68641
P447B15 and P68640.
Go to paragraph 1123.
NO
Go to step 6.
5. (ACA) Check for open between:
P235C and P68640,
P235D and P68641.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to step 7.
6. (ACB) Check for open between:
J2353 and P68640,
J2354 and P68641.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to step 9.