TM 1-1520-238-T-7
11281
1156.
RTR BRK CIRCUIT BREAKER DOES NOT STAY CLOSED WITH BUCS TST
1156
SWITCH SET TO CPG (cont)
9. Check for short between between P686127
and ground.
Does short exist?
YES
Repair shorted wire between:
P686127 and P459A6,
J459A6 and J2682.
Go to paragraph 1123.
NO
Go to step 10.
10. Check for short between P686128 and ground.
Does short exist?
YES
Repair shorted wire between:
P686127 and P459A2,
P459A2 and J2684.
Go to paragraph 1123.
NO
Replace CPG collective SPAD
(TM 1-1520-238-23).
11. Check for short between P413B16 and ground.
Does short exist?
YES
Go to step 12.
NO
Go to step 15.
12. Detach P1 from J266. Check for short between
P413B16 and ground.
Does short exist?
YES
Repair shorted wire between
P413B16 and J2663.
Go to paragraph 1123.
NO
Go to step 13.
13. Check for short between P686123 and ground.
Does short exist?
YES
Repair shorted wire between:
P686123 and P459A18,
J459A18 and J2662.
Go to paragraph 1123.
NO
Go to step 14.
14. Check for short between P686124 and ground.
Does short exist?
YES
Repair shorted wire between:
P686124 and P459A5,
J459A5 and J2664.
Go to paragraph 1123.
NO
Replace CPG lateral SPAD
(TM 1-1520-238-23).
15. Check for short between P472A2 and ground.
Does short exist?
YES
Go to step 16.
NO
Go to step 19.
16. Detach J273. Check for short between
P472A2 and ground.
Does short exist?
YES
Repair shorted wire between
P472A2 and J2733.
Go to paragraph 1123.
NO
Go to step 17.
17. Check for short between P686125 and ground.
Does short exist?
YES
Repair shorted wire between:
P686125 and P459A20,
J459A20 and J908A2,
P908A2 and J2732.
Go to paragraph 1123.
NO
Go to step 18.
18. Check for short between P686126 and ground.
Does short exist?
YES
Repair shorted wire between:
P686126 and P459A4,
J459A4 and J908A4,
P908A4 and J2734.
Go to paragraph 1123.
NO
Replace CPG directional SPAD
(TM 1-1520-238-23).