TM 1-1520-238-T-7
11292
1163. CPG LAT LVDT NO-GO CPG COMPARTMENT APPEARS ON HOD
1163
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Place CPG cyclic stick to full right or full left.
Detach P688. Check for 10 VAC at P68637.
Is voltage present?
YES
(ACA) Replace DASEC
(TM 1-1520-238-23).
(ACB) Go to step 2.
NO
(ACA) Go to step 3.
(ACB) Go to step 4.
2. (ACB) Attach P686. Detach filter adapter A707.
Check for 10 VAC at A70737.
Is voltage present?
YES
Replace DASEC
(TM 1-1520-238-23).
NO
Replace
(TM 1-1520-238-23).
3. (ACA) Detach P686. Check for short between:
P237C and ground,
P237D and ground.
Does short exist?
YES
Repair shorted wire between:
P237D and J447B11,
P237C and J447B12,
P447B11 and P68637,
P447B12 and P68636.
Go to paragraph 1123.
NO
Go to step 5.
4. (ACB) Detach P686. Check for short between:
J2373 and ground,
J2374 and ground.
Does short exist?
YES
Repair shorted wire between:
J2374 and J447B11,
J2373 and J447B12,
P447B11 and P68637,
P447B12 and P68636.
Go to paragraph 1123.
NO
Go to step 6.
5. (ACA) Check for open between:
P237C and P68636,
P237D and P68637.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to step 7.
6. (ACB) Check for open between:
J2373 and P68636,
J2374 and P68637.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to step 9.
7. (ACA) Attach P686. Check for 26 VAC at
P237A.
Is voltage present?
YES
Go to step 8.
NO
Go to step 11.