TM 1-1520-238-T-7
11294
1164. DASE ENGAGE PANEL NO-GO PLT COMPARTMENT APPEARS ON HOD
1164
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. On pilot ASE panel, set PITCH switch to on.
Does PITCH switch stay engaged?
YES
Go to step 4.
NO
Go to step 2.
2. With PITCH switch held to on position, check for
28 VDC at P688116.
Is voltage present?
YES
Go to step 7.
NO
Go to step 3.
3. Check for open between P170B4 and
P688116.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Replace pilot ASE panel
(TM 1-1520-238-23).
4. On pilot ASE panel, set ROLL switch to on.
Does ROLL switch stay engaged?
YES
Go to step 11.
NO
Go to step 5.
5. With ROLL switch held to on position, check for
28 VDC at P688117.
Is voltage present?
YES
Go to step 8.
NO
Go to step 6.
6. Check for open between P688117 and
P170A8.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Replace pilot ASE panel
(TM 1-1520-238-23).
7. Check for open between P170B10 and
P638119.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
(ACA) Replace DASEC
(TM 1-1520-238-23).
(ACB) Go to step 9.
8. Check for open between P170B3 and
P683120.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
(ACA) Replace DASEC
(TM 1-1520-238-23).
(ACB) Go to step 10.
9. (ACB) Detach filter adapter A706. Check for
open through pin A706119.
Does open exist?
YES
Replace filter adapter
(TM 1-1520-238-23).
NO
Replace DASEC
(TM 1-1520-238-23).