TM 1-1520-238-T-7
11291
1162.
ALL NO-GO MESSAGES EXCEPT GROUP D NO-GO APPEARS ON HOD
1162
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-T-6
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check for 28 VDC at P686118.
Is voltage present?
YES
(ACA) Replace DASEC
(TM 1-1520-238-23).
(ACB) Go to step 5.
NO
Go to step 2.
2. Check for open between (A402)TB27K and
P686118.
Does open exist?
YES
Go to step 4.
NO
Go to step 3.
3. Check for open between (A402):
TB27D and J134.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Refer toTM 1-1520-238-T-6 to
troubleshoot circuit protection
system (dc essential bus 3
pilot station).
4. Check for open between (A402):
K41/2B2 and J27B4.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to step 6.
5. (ACB) Detach filter adapter A707. Check for
open through pin A707118.
Does open exist?
YES
Replace filter adapter
(TM 1-1520-238-23).
NO
Replace DASEC
(TM 1-1520-238-23).
6. Check for open between (A402):
TB27K and K41/2B3.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Replace relay (A402)XK41/2
(TM 1-1520-238-23).
END OF TASK