TM 1-1520-238-T-7
11290
1161. CPG CYCLIC GRIP NO-GO-CPG-COMPARTMENT APPEARS ON HOD
1161
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. On CPG cyclic stick, press and hold TRIM
switch, check for 28 VDC at P686116.
Is voltage present?
YES
(ACA) Replace DASEC
(TM 1-1520-238-23).
(ACB) Go to step 3.
NO
(ACB) Go to step 2.
2. (ACB) Check for open between:
P686116 and J1187,
J1186 and (A402)TB39M.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Replace CPG cyclic stick
(TM 1-1520-238-23).
3. (ACB) Detach filter adapter A707. Check for
open through pin A707116.
Does open exist?
YES
Replace filter adapter
(TM 1-1520-238-23).
NO
Replace DASEC
(TM 1-1520-238-23).
END OF TASK