TM 1-1520-238-T-7
Change 3
11299
1167. PILOT LONG 1 DCPLR NO-GO PLT COMPARTMENT OR PILOT LONG 2 DCPLR
1167
NO-GO PLT COMPARTMENT APPEARS ON HOD
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. With BUCS TST switch held in PLT or CPG
position, check for 28 VDC at P688115 and
P688122.
Is voltage present?
YES
Go to step 2.
NO
Go to step 4.
2. Check pilot cyclic longitudinal SPAD shear pin
condition (TM 1-1520-238-23).
Is shear pin sheared?
YES
Replace SPAD shear pin
(TM 1-1520-238-23).
NO
Go to step 3.
3. Detach P472 and P459. Check for short
between:
J2711 and J2712,
J2711 and J2714.
Does short exist?
YES
Repair shorted wire between:
J2711 and P472A20,
J2712 and P912B1,
J2714 and P908A3,
J912B1 and J459A7,
J908A3 and J459A11.
Go to paragraph 1123.
NO
Replace longitudinal SPAD
(TM 1-1520-238-23).
4. Check for open between:
J2712 and P688115,
J2714 and P688122.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to step 5.
5. Check for open between:
P12 and P13,
P13 and P14.
Does open exist?
YES
Replace longitudinal SPAD
(TM 1-1520-238-23).
NO
(ACA) Replace DASEC
(TM 1-1520-238-23).
(ACB) Go to step 6.
6. (ACB) Detach filter adapter A708. Check for
open through pins A708115 and A708122.
Does open exist?
YES
Replace filter adapter
(TM 1-1520-238-23).
NO
Replace DASEC
(TM 1-1520-238-23).
END OF TASK