TM 1-1520-238-T-7
11331
1183. PILOT LAT LVDT NO-GO PLT COMPARTMENT APPEARS ON HOD
1183
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Place pilot cyclic stick to full right or full left.
Detach P688. Check for 10 VAC at P688.
Is voltage present?
YES
(ACA) Replace DASEC
(TM 1-1520-238-23).
(ACB) Go to step 2.
NO
(ACA) Go to step 3.
(ACB) Go to step 4.
2. (ACB) Attach P688. Detach filter adapter A708.
Check for 10 VAC at A70810.
Is voltage present?
YES
Replace filter adapter
(TM 1-1520-238-23).
NO
Replace DASEC
(TM 1-1520-238-23).
3. (ACA) Check for short between:
P233C and ground,
P233D and ground.
Does short exist?
YES
Repair shorted wire between:
P233D and J459B10,
P233C and J459B11,
P459B10 and P68810,
P459B11 and P6889.
Go to paragraph 1123.
NO
Go to step 5.
4. (ACB) Check for short between:
J2333 and ground,
J2334 and ground.
Does short exist?
YES
Repair shorted wire between:
J2334 and J459B10,
J2333 and J459B11,
P459B10 and P68810,
P459B11 and P6889.
Go to paragraph 1123.
NO
Go to step 6.
5. Check for open between:
P233C and P6889,
P233D and P68810.
Is voltage present?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to step 7.
6. (ACB) Check for open between:
J2333 and P6889,
J2334 and P68810.
Is voltage present?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to step 9 .