TM 1-1520-238-T-7
11339
1187. CPG LONG LVDT NO-GO CPG COMPARTMENT APPEARS ON HOD (cont)
1187
7. (ACA) Attach P686. Check for 26 VAC at
P236A.
Is voltage present?
YES
Go to step 8.
NO
Go to step 11.
8. (ACA) Check for open between P236B and
P499B17.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Replace CPG longitudinal
(pitch) LVDT
(TM 1-1520-238-23).
9. (ACB) Attach P686. Check for 26 VAC at
J2361.
Is voltage present?
YES
Go to step 10.
NO
Go to step 12.
10. (ACB) Check for open between J2362 and
P6936.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Replace CPG longitudinal
(pitch) LVDT
(TM 1-1520-238-23).
11. (ACA) Check for open between J236A and
P499B16.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to paragraph 1177.
12. (ACB) Check for open between J2361 and
P6935.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to paragraph 1177.