TM 1-1520-238-T-7
11338
Change 3
1187. CPG LONG LVDT NO-GO CPG COMPARTMENT APPEARS ON HOD
1187
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Place CPG cyclic stick to full forward or full aft.
Check for 2.5 VAC at P68827.
Is voltage present?
YES
(ACA) Replace DASEC
(TM 1-1520-238-23).
(ACB) Go to step 2.
NO
(ACA) Go to step 3.
(ACB) Go to step 4.
2. (ACB) Attach P686. Detach filter adapter A707.
Check for 10 VAC at A70727.
Is voltage present?
YES
Replace DASEC
(TM 1-1520-238-23).
NO
Replace filter adapter
(TM 1-1520-238-23).
3. (ACA) Detach P686. Check for short between:
P236C and ground,
P236D and ground.
Does short exist?
YES
Repair shorted wire between:
P236D and P912B14,
P236C and P912B15,
J912B14 and J447B8,
J912B15 and J447B9,
P447B8 and P68627,
P447B9 and P68626.
Go to paragraph 1123.
NO
Go to step 5.
4. (ACB) Check for short between:
J2363 and ground,
J2364 and ground.
Does short exist?
YES
Repair shorted wire between:
J2364 and P912B14,
J2363 and P912B15
J912B14 and J447B8,
J912B15 and J447B9,
P447B8 and P68627,
P447B9 and P68626.
Go to paragraph 1123.
NO
Go to step 6.
5. (ACA) Check for open between:
P236C and P68626,
P236D and P68627.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to step 7.
6. (ACB) Check for open between:
J2363 and P68626,
J2364 and P68627.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to step 9.