TM 1-1520-238-T-7
11335
1185. PILOT COLL LVDT NO-GO PLT COMPARTMENT APPEARS ON HOD
1185
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Place pilot collective stick to full up or full down.
Check for 10 VAC at P68821.
Is voltage present?
YES
(ACA) Replace DASEC
(TM 1-1520-238-23).
(ACB) Go to step 2.
NO
(ACA) Go to step 3.
(ACB) Go to step 4.
2. (ACB) Attach P688. Detach filter adapter A708.
Check for 10 VAC at A70821.
Is voltage present?
YES
Replace DASEC
(TM 1-1520-238-23).
NO
Replace filter adapter
(TM 1-1520-238-23).
3. (ACA) Detach P688. Check for short between:
P230C and ground,
P230D and ground.
Does short exist?
YES
Repair shorted wire between:
P230D and J459B14,
P230C and J459B15,
P459B14 and P68820,
P459B15 and P68821.
Go to paragraph 1123.
NO
Go to step 5.
4. (ACB) Check for short between:
J2303 and ground,
J2304 and ground.
Does short exist?
YES
Repair shorted wire between:
J2304 and J459B14,
J2303 and J459B15,
P459B14 and P68820,
P459B15 and P68821.
Go to paragraph 1123.
NO
Go to step 6.
5. (ACA) Check for open between:
P230C and P68821,
P230D and P68820.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to step 7.
6. (ACB) Check for open between:
J2303 and P68821,
J2304 and P68820.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to step 9.
7. (ACA) Attach P688. Check for 26 VAC at
P230A.
Is voltage present?
YES
Go to step 8.
NO
Go to step 11.