TM 1-1520-238-T-7
Change 3
11337
1186. AIR DATA PROCESSOR NOGO AFT AVIONICS BAY APPEARS ON HOD
1186
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 9-1230-476-20-1
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check for open between:
P68628 and P9446,
P68629 and P9445.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to step 2.
2. Detach P686. Check for short between:
P9446 and ground,
P9445 and ground.
Does short exist?
YES
Replace air data processor
(TM 9-1230-476-20-1).
NO
(ACA) Replace DASEC
(TM 1-1520-238-23).
(ACB) Go to step 3.
3. (ACB) Attach P686. Detach filter adapter A707,
check for open between:
A70728 and P9446,
A70729 and P9445.
Does open exist?
YES
Replace filter adapter
(TM 1-1520-238-23).
NO
Go to step 4.
4. (ACB) Check for short between:
A70728 and ground,
A70729 and ground.
Does short exist?
YES
Replace filter adapter
(TM 1-1520-238-23).
NO
Replace DASEC
(TM 1-1520-238-23).
END OF TASK