TM 1-1520-238-T-7
11374
Change 5
1190.
STAB MAN AC CIRCUIT BREAKER DOES NOT STAY CLOSED
1190
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
References:
TM 1-1520-238-T-6
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
L200 panel removed
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Open STAB MAN AC (A76)CB7 circuit breaker.
Detach P1 from (A402)J1.
Check for short between P137 and ground.
Does short exist?
YES
Refer to TM 1-1520-238-T-6
to troubleshoot circuit protection
system (ac essential bus 1
pilot station).
NO
Go to step 2.
2. (AAG) Depin (A402)GS1H.
Check for short between (A402)J137 and
ground.
Does short exist?
YES
Repair shorted wire in A402.
Go to paragraph 1188, or
replace (A402)T3
(TM 1-1520-238-23).
NO
Go to step 3.
3. (ABC) Depin (A402)GS9H.
Check for short between (A402)J137 and
ground.
Does short exist?
YES
Repair shorted wire in A402.
Go to paragraph 1188, or
replace (A402)T3
(TM 1-1520-238-23).
NO
Go to step 4.
4. Depin (A402)TB317T.
Detach:
P441 from (A402)J24,
P431 from (A402)J27.
Check for short between (A402)J24B19 and
ground.
Does short exist?
YES
Repair shorted wire between
(A402):
J24B19 and TB317S,
J27A16 and TB317R.
TB317N and ground.
Go to paragraph 1188, or
replace T3 (TM 1-1520-238-23).
NO
Go to step 5.
5. Check for short between P441B19 and ground.
Does short exist?
YES
Go to step 6.
NO
Go to step 10.