TM 1-1520-238-T-7
11376.2
Change 5
1191.
STAB MAN DC CIRCUIT BREAKER DOES NOT STAY CLOSED (cont)
1191
14. Check for short between:
P437E and ground,
P437B and ground.
Does short exist?
YES
Go to step 15.
NO
Go to step 16.
15. Detach J993 from (A641)P1.
Check for short between:
P437E and ground,
P437B and ground.
Does short exist?
YES
Repair shorted wire between
P437E and J993D,
P437B and J993A.
Go to paragraph 1188.
NO
Replace PLT MAN STAB CONT
switch (A641)
(TM 1-1520-238-23).
16. Check for short between P427G and ground.
Does short exist?
YES
Go to step 17.
NO
Go to step 19.
17. Detach P485 from (A323)J7.
Check for short between P427G and ground.
Does short exist?
YES
Repair shorted wire between
P427G and P485R.
Go to paragraph 1188.
NO
Go to step 18.
18. With MAN CONT NOSE UP (A323)K13 relay
removed,
check for short between (A323)J7R and
ground.
Does short exist?
YES
Repair shorted wire between
(A323)J7R and XK13X1.
Go to paragraph 1188.
NO
Replace MAN CONT NOSE UP
relay (A323)K13
(TM 1-1520-238-23).
19. Check for short between P431B10 and ground.
Does short exist?
YES
Go to step 20.
NO
Go to step 23.
20. Detach P1077 from (A329)J1.
Check for short between P431B10 and ground.
Does short exist?
YES
Repair shorted wire between
P431B10 and P1077L.
Go to paragraph 1188.
NO
Go to step 21.
21. Check for short from P1077S and ground.
Does short exist?
YES
Go to step 22.
NO
Repair shorted wire between
(A329):
TB13E and TB11/2G,
TB13B and TB11/2F,
J1L and TB11/2C,
TB11/2H and TB13H,
TB13L and J1S,
Go to paragraph 1188.