TM 1-1520-238-T-7
Change 5
11375
1190. STAB MAN AC CIRCUIT BREAKER DOES NOT STAY CLOSED (cont)
1190
6. Detach P413 from (A326)J10.
Check for short between P413B10 and ground.
Does short exist?
YES
Repair shorted wire between
P441B19 and P413B10.
Go to paragraph 1188.
NO
Go to step 7.
7. Detach P472 from (A326)J15.
Check for short between (A326)J15A8 and
ground.
Does short exist?
YES
Repair shorted wire between
(A326):
J10B10 and TB117Y,
TB117T and J10B17,
TB117W and J15A8.
Go to paragraph 1188.
NO
Go to step 8.
8. Detach P982 from (M52)J1.
Check for short between P982D and ground.
Does short exist?
YES
Repair shorted wire between
P982D and P472A8.
Go to paragraph 1188.
NO
Go to step 9.
9. Detach P981 from (M51)J1.
Check for short between P981D and ground.
Does short exist?
YES
Repair shorted wire between
P981D and P413B17.
Go to paragraph 1188.
NO
Replace pilot STAB POS IND
(M51) or CPG STAB POS IND
(M52)
(TM 1-1520-238-23).
10. Detach (MT19)P1076 from J1076.
Check for short between P431A16 and ground.
Does short exist?
YES
Repair shorted wire between:
J402B5 and P431A16.
P402B5 and J1076E.
Go to paragraph 1188.
NO
Replace STAB POS TRANS
transducer (MT19)
(TM 1-1520-238-23).
END OF TASK