TM 1-1520-238-T-7
Change 5
11376.3
1191.
STAB MAN DC CIRCUIT BREAKER DOES NOT STAY CLOSED (cont)
1191
22. Detach P991 from (A638)J3R.
Check for short between P1077S and ground.
Does short exist?
YES
Repair shorted wire between
P1077R and P991R.
Go to paragraph 1188.
NO
Replace STAB CONT UNIT 2
(A638) (TM 1-1520-238-23).
23. Attach P1077 to (A637)J3.
Check for short between P427H and ground.
Does short exist?
YES
Go to step 24.
NO
Go to step 25.
24. Detach P1077 from (A637)J3.
Check for short between P427H and ground.
Does short exist?
YES
Repair shorted wire between
P427H and P1077m.
Go to paragraph 1188.
NO
Repair shorted wire between
(A329):
J1m and TB15B,
TB15F and TB11/2B,
TB15D and (XK15)X1.
Go to paragraph 1188.
or replace MAN CONT NOSE
DOWN relay (A329)K15
(TM 1-1520-238-23).
25. Detach P996 from (L46)J996.
Check for short between (L46)J996J and
(L46)J996K.
Does short exist?
YES
Replace bottom STABILATOR
ACTUATOR (L46)
(TM 1-1520-238-23).
NO
Go to step 26.
26. Detach P995 from (L46)J995.
Check for short between (L46)J995J and
(L46)J995K.
Does short exist?
YES
Replace top STABILATOR
ACTUATOR (L46)
(TM 1-1520-238-23).
NO
Go to step 27.
27. Remove MAN CONT NOSE UP (A323)K13.
Check for short between:
(A323)XK13B2 and ground,
P485M and ground,
(A329)J1c and ground,
(A329)XK11/2A2 and ground,
P1077f and ground.
Does short exist?
YES
Repair shorted wire between:
(A323)XK13B2 and
(A323)J7M,
P485M and P1077c,
(A329)J1c and XK11/2A3,
(A329)XK11/2A2 and J1f,
P1077f and P995J.
Go to paragraph 1188.
NO
Go to step 28.
28. Check for short between:
(A323)XK13A2 and ground,
(A323)XK11/2A2 and ground,
P485F and ground.
Does short exist?
YES
Repair shorted wire between:,
(A323)XK13A2 and
XK11/2A3,
(A323)XK11/2A2 and J7F,
P485F and P996J.
Go to paragraph 1188.
NO
Go to step 29.