TM 1-1520-238-T-7
Change 5
11381
1195.
CPG STAB POS INDICATOR EDGE-LIGHT DOES NOT LIGHT
1195
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-T-6
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Detach P982 from (M52)J1.
Check for 5 VDC between P982F and P982G.
Is voltage present?
YES
Replace CPG STAB POS
indicator (M52)
(TM 1-1520-238-23).
NO
Go to step 2.
2. On CPG INTR LT panel rotate INST control
CCW to OFF.
Check for open between P982F and
(A326)TB141B.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Go to step 3.
3. Check for short between
P982F and ground.
Does short exist?
YES
Repair shorted wire.
Go to paragraph 1188.
NO
Go to step 4.
4. Check for open between P982G and
(A326)TB140B.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Troubleshoot CPG edge lights
(TM 1-1520-238-T-6)
.
END OF TASK