TM 1-1520-238-T-7
11376.4
Change 5
1191. STAB MAN DC CIRCUIT BREAKER DOES NOT STAY CLOSED (cont)
1191
29. Remove MAN CONT NOSE DOWN (A329)K15
relay. Check for short between:
(A329)XK15B2 and ground,
(A329)XK11/2C2 and ground,
P1077g and ground.
Does short exist?
YES
Repair shorted wire between:
(A329)XK15B2 and
XK11/2C3,
(A329)XK11/2C2 and J1g,
P1077g and P995K.
Go to paragraph 1188.
NO
Go to step 30.
30. Check for short between:
(A329)XK15A2 and ground,
P1077b and ground,
(A323)J7s and ground,
(A323)XK11/2C2,
P485A and ground.
Does short exist?
YES
Repair shorted wire between:
(A329)XK15A2 and J1b,
P1077b and P485S,
(A323)J7s and XK11/2C3,
(A323)XK11/2C2 and J7A,
P485A and and P996K.
Go to paragraph 1188.
NO
Replace:
AUTO/MAN PWR relay
(A323)K11/2, or
AUTO/MAN PWR relay
(A329)K11/2
(TM 1-1520-238-23).
END OF TASK