TM 1-1520-238-T-7
Change 5
11384.1/(11384.2 blank)
1197. STAB AUTO DC CIRCUIT BREAKER DOES NOT STAY CLOSED (cont)
1197
17. Check for short between (A329):
J1a and ground,
J1n and ground,
J1C and ground,
J1A and ground.
Does short exist?
YES
Repair shorted wire between
(A329):
J1A and XK17X1,
J1C and XK18X1,
J1a and XK11/2B2,
XK11/2B1 and J1n,
or replace: APPROACH 1
LIGHT relay (K17) or
AUTO/MAN PWR relay
(K11/2) or APPROACH 2
AUDIO relay (K18).
Go to paragraph 1188.
NO
Go to step 18.
18. Detach P989. Check for short between P1077n
and ground.
Does short exist?
YES
Repair shorted wire between
P989G and P1077n.
Go to paragraph 1188.
NO
Replace STAB CONT UNIT 2
(A638)
(TM 1-1520-238-23).
END OF TASK