TM 1-1520-238-T-7
11386
Change 5
1198. STABILATOR DOES NOT MOVE EITHER UP OR DOWN OR STAB MAN DC CIRCUIT
1198
BREAKER DOES NOT STAY CLOSED (cont)
6. Detach P1077 from (A329)J1.
Check for short between:
P991S and ground,
P987S and ground,
(A329)J1G and ground,
(A329)TB11/2A and ground.
Does short exist?
YES
Repair shorted wire between:
P991S and P987R,
P987S and P1077G,
(A329)J1G and
(A329)XK13/4X1,
(A329)XK13/4D2 and
(A329)TB11/2A.
Go to paragraph 1188.
NO
Go to step 7.
7. Check for open between (A329)XK13/4X2
and (A329)XK16B3.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Replace AUTO RESET relay
(A329)K16, or
MAN MODE LOCK SELECT
relay (A329)K13/4, or
STAB CONT UNIT 1 (A637), or
STAB CONT UNIT 2
(TM 1-1520-238-23).
END OF TASK