TM 1-1520-238-T-7
11388
Change 5
11100. PILOT AND/OR CPG STAB POS INDICATORS DO NOT INDICATE FULL NOSE UP
11100
POS (9 2), FULL DOWN (35 2), OR OFF FLAG APPEARS
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Extractor, Relay
CTJ-RO6
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-T-6
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
L325 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check for 115 VAC at (A76)P137.
Is voltage present?
YES
Go to step 2.
NO
Refer to TM 1-1520-238-T-6 to
troubleshoot circuit protection
system (ac essential bus 1 pilot
station).
2. Open STAB MAN AC (A76)CB7 circuit breaker.
Check for open between:
(A402)J137 and T31,
(A402)T32 and GS9H,
P962H and GS263A,
P961H and GS433E,
P1076D and GS89F.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Go to step 3.
3. Close STAB MAN AC (A76)CB7 circuit breaker.
Detach P441 from (A402)J24.
Check for 26 VAC between (A402):
J24B20 and J24B19.
Is voltage present?
YES
Go to step 4.
NO
Repair open wire between
(A402):
T33 and TB317N,
TB317S and J24B19,
T35 and TB317T,
TB317W and J24B20,
TB317Z and GS9G.
Go to paragraph 1188, or
replace transformer (A402)T3
(TM 1-1520-238-23).