TM 1-1520-238-T-7
11422
Change 5
11122. NOE/APRCH SWITCH DISENGAGES OR STAB POS INDICATORS DO NOT
11122
INDICATE 25 2 (cont)
5. Apply 28 VDC to (A137) J1A1 and 28 VDC
return to (A137) J1B2.
Set NOE/APRCH switch to NOE/APRCH.
Remove pilot ASE panel (A137) for J1B7 (HI)
and J1B2 (LO) voltage measurement.
Check for 28 VDC between (A137) J1B7 (HI)
and J1B2 (LO).
Does NOE/APRCH switch remain set and is
voltage present?
YES
Go to step 6.
NO
Replace pilot ASE panel (A137)
(TM 1-1520-238-23).
6. Detach:
P990 from (A638)J2,
P986 from (A637)J2.
Check for short between P170B7 and ground.
Does short exist?
YES
Repair shorted wire between:
P170B7 and J447A11,
P447A11 and P485B,
(A323)J7B and
(A323)TB22C,
(A323)TB22F and
(A323)J7C,
(A323)TB22J and
(A323)J7D,
P485C and P990S,
P485D and P986S.
Go to paragraph 1188.
NO
Replace STAB CONT UNIT 1
(A637) or
STAB CONT UNIT 2 (A638)
(TM 1-1520-238-23).
END OF TASK
Paragraph 11123 deleted