TM 1-1520-238-T-7
Change 5
11425
11124. ENG WARN CIRCUIT BREAKER DOES NOT STAY CLOSED (cont)
11124
5. Detach P1077 from (A323)J2).
Check for short between (A329)J1D and
ground.
Does short exist?
YES
Repair shorted wire between:
P469A18 and J447A8,
P447A8 and P1077D,
(A329)J1D and
(A329)XK16X1.
Go to paragraph 1188, or
replace AUTO RESET
(A329)XK16 relay
(TM 1-1520-238-23).
NO
Go to step 6.
6. Detach P49 from (A9)J1. Check for short
between P435A15 and ground.
Does short exist?
YES
Repair shorted wire.
Go to paragraph 1188.
NO
Replace ENG OUT WARN unit
(A9) (TM 1-1520-238-23).
END OF TASK