TM 1-1520-238-T-7
(11423 blank)/11424
Change 5
11124. ENG WARN CIRCUIT BREAKER DOES NOT STAY CLOSED
11124
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-T-6
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Nontransparent
barrier removed
Access provisions
L325, T290L, T290R,
T250L and T250R
doors open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Open STAB MAN DC (A76)CB6, STAB AUTO
DC (A76)CB3, STAB AUTO AC (A76)CB2, and
ENG WARN (A76)CB52 circuit breakers.
Detach P469 from (A326)J2.
Check for short between P469A10 and ground.
Does short exist?
YES
Go to step 2.
NO
Go to step 3.
2. Detach P463 from (A76)J1.
Check for short between P469A10 and ground.
Does short exist?
YES
Repair shorted wire between
P469A10 and P463N.
Go to paragraph 1188.
NO
Refer to TM 1-1520-238-T-6 to
troubleshoot circuit protection
system (dc emergency bus
pilot station).
3. (AAV)Detach:
P469 from (A326)J2,
P435 from (A326)J7.
Check for short between (A329)J1D and
ground.
Does short exist?
YES
Repair shorted wire between
(A326):
TB151F and J2A18.
Go to paragraph 1188.
NO
Go to step 4.
4. Detach:
P469 from (A326)J2,
P435 from (A326)J7.
Check for short between (A326)J7A15 and
ground.
Does short exist?
YES
Repair shorted wire between
(A326):
J7A15 and TB151D,
TB151E and J2A10.
Go to paragraph 1188.
NO
Go to step 5.