TM 1-1520-238-T-7
11426
Change 5
11125. ND/NU SET TO ND TOP PISTON FAILS TO MOVE STABILATOR
11125
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Extractor, Relay
CTJ-RO6
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Detach P995 from (L46)J995.
Momentarily press PLT NU/ND switch to ND.
Check for 28 VDC between P995K(HI) and
P995J(LO).
Is voltage present?
YES
Replace top STAB ACTUATOR
(L46) (TM 1-1520-238-23).
NO
Go to step 2.
2. Open STAB MAN DC (A76)CB6, STAB AUTO
DC (A76)CB3, STAB AUTO AC (A76)CB2, and
ENG WARN (A76)CB52 circuit breakers.
Detach P427 from (A402)J28.
Check for open between (A402):
J28A and TB224B.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Go to step 3.
3. Detach P1077 from (A329)J1.
Check for open between P427A and P1077k.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Go to step 4.
4. Check for open between (A329):
J1k and XK15B1.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Go to step 5.
5. Check for open between (A323)XK13B3 and
GS4B.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Replace MAN CONT NOSE
DOWN relay (A329)K15, or
AUTO/MAN PWR relay
(A329)K11/2, or MAN CONT
NOSE UP relay (A323)K13
(TM 1-1520-238-23).
END OF TASK