TM 1-1520-238-T-7
Change 5
11427
11126. ND/NU SET TO ND BOTTOM PISTON FAILS TO MOVE STABILATOR
11126
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Extractor, Relay
CTJ-RO6
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Detach P996 from (L46)J996.
Move pilot NU/ND switch to ND.
Check for 28 VDC between P996K(HI) and
P996J(LO).
Is voltage present?
YES
Replace bottom STAB
ACTUATOR (L46)
(TM 1-1520-238-23).
NO
Go to step 2.
2. Open STAB MAN DC (A76)CB6, STAB AUTO
DC (A76)CB3, STAB AUTO AC (A76)CB2, and
ENG WARN (A76)CB52 circuit breakers.
Detach P427 from (A402)J28.
Check for open between (A402):
J28B and TB224C.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Go to step 3.
3. Detach P1077 from (A329)J1.
Check for open between P427B and P1077h.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Go to step 4.
4. Check for open between P1077h and
(A329)TB15A.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Go to step 5.
5. Check for open between (A329):
TB15E and XK15A1.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Go to step 6.
6. Check for open between (A323):
XK13A3 and GS4C.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Replace MAN CONT NOSE
DOWN relay (A329)K15, or
AUTO MAN PWR relay
(A323)K11/2, or
MAN CONT NOSE UP relay
(A323)K13.
(TM 1-1520-238-23).
END OF TASK