TM 1-1520-238-23
2-651
2.180.
TRANSPARENT CREW PROTECTION ARMOR BARRIER REPLACEMENT continued
NOTE
FIRE PULL switches are manufac-
tured with the T-handle mounting
screws installed from top or bottom of
switch shaft.
Pilot FIRE PULL switches are re-
moved to provide clearance for remov-
al/installation of the transparent
barrier, and are not completely re-
moved from the helicopter for this task.
g. Remove pilot FIRE PULL switches (28) and
(29) from pilot instrument panel (30).
(1) Pull T-handles (31) and (32) to extended
position.
(2) Remove two screws (33).
(3) Remove T-handles (31) and (32) from
switches (28) and (29).
(4) Remove four screws (34) from panel (30).
(5) Withdraw switches (28) and (29) forward from
back of panel (30).
(6) Install T-handle (31) and screw (33) on switch
(28).
(7) Install T-handle (32) and screw (33) on switch
(29).
(8) Position switches (28) and (29) clear of area
directly under transparent barrier (26).
GO TO NEXT PAGE
PILOT STATION
M04-3437-17
31
32
33
28
30
34
29
34
33
M04-3437-18
26
29
28
M04-3437-19