TM 1-1520-238-23
4-591
4.169.
CPG POWER QUADRANT DISASSEMBLY/ASSEMBLY (AVIM) continued
f. Assemble power lever assembly (10).
NOTE
The following step is typical for right or
left power levers.
(1) Install trigger release (35) in power lever (45).
(a) Install two screws (51) through bar (50)
into trigger release (35).
(b) Install bar (50) on lever (45).
(c) Install screw (48) through guide (49) into
lever (45).
(d) Install two screws (46) through upper re-
taining plate (47) into lever (45).
NOTE
The lever assembly may have had one or
more shims installed. Install same num-
ber of shims recorded during disassem-
bly.
(2) Install fiber spacer (44), right lever (43), and
fiber spacer (42) on power lever shaft (24).
(3) Install fiber spacer (40) and left lever (41) on
power lever shaft (24).
(4) Install flat washer (38) and shims (39) on
power lever shaft (24).
GO TO NEXT PAGE
35
50
51
47
46
49
48
45
M04-3927-19
M04-3927-20
38
39
40
41
42
43
24
44
10