4.182.
NO. 1 ENGINE POWER AVAILABLE SPINDLE (PAS) RIGGING PROCEDURE continued
ac. Verify lockout by ensuring scribed line (35) on
Woodward HMU (32) is fully visible.
ad. At HMU (32), verify that spindle cam (34) does
not contact spindle stop (33).
NOTE
If Woodward HMU is installed, spindle
cam is allowed to contact spindle stop.
ae. Adjust power lever (3) maximum stop screw
(2).
(1) With power lever (3) in LOCKOUT position,
adjust screw (2) until it touches power lever
(3).
af. Set power lever (3) to IDLE.