4.197.6. Installation
a. Install switch (9) in power quadrant (10).
(1) Install wires of switch (9) through grommet
(17) in support plate (18).
(2) Install two screws (16) through washers (15),
plate (18), spacer (14), switch actuator (13),
switch (9), lockwashers (12), and locknuts
(11). Do not tighten locknuts (11).
(3) Apply sealing compound to threads of two
screws (16). Use sealing compound
(item 172, App F)
b. Adjust switch (9).
(1) Set power lever (19) to FLY.
(2) Adjust switch (9) so actuator (13) is fully de-
pressed.
(3) Move power lever (19) back from FLY, ensure
switch (9) is in open position.
c. Tighten two locknuts (11).