TM 1-1520-238-23
8-98
8.38.
PITOT STATIC SYSTEM TUBING TRANSITION REPLACEMENT continued
NOTE
This task is typical for all transitions in the
pitot static system.
8.38.3. Removal
WARNING
Do not place heater near flammable
material or allow heater to contact
skin: severe burns can result. Wear
protective equipment. If injury occurs,
seek medical aid.
a. Remove transition (1) from convoluted tubing
(2).
(1) Heat transition (1). Use protective gloves and
heater.
(2) While transition (1) is hot, hold smooth tube
(3).
(3) Remove convoluted tubing (2).
b. Remove transition (1) from smooth tubing (3).
(1) Heat transition (1). Use protective gloves and
heater.
(2) While transition (1) is hot, hold smooth tubing
(3) and remove transition (1).
GO TO NEXT PAGE
M04-3731-1
2
1
3
M04-3731-5
1
3