TM 1-1520-238-23
9-40
9.10.
ELECTRICAL POWER DISTRIBUTION BOX RELAY COVER REMOVAL/INSTALLATION continued
c. Identify and depin three wires (1) from splices
(2) (TM 55-1500-323-24).
(1) Remove tiedown straps as required.
d. Remove relay cover (3) from electrical power
distribution box (4).
(1) Loosen six captive screws (5) from box (4).
9.10.4. Cleaning
a. Clean removed and attaching parts (para
1.47).
9.10.5. Inspection
a. Check removed and attaching parts for dam-
age (para 9.1).
b. Check wires for wear, cuts, breaks, and dam-
aged splices (para 9.1).
c. Check gasket for rips, cracks, or tears. None
allowed.
d. Check removed and attaching parts for corro-
sion (para 1.49).
e. Check tie anchor for damage (para 9.1).
9.10.6. Repair
a. Remove gasket (6) from cover (3). Use putty
knife.
b. Remove excess adhesive and clean gasket
mounting area of relay cover (para 1.47).
c. Check gasket mounting area for corrosion
(para 1.49).