TM 1-1520-238-23
9-39
9.10.
ELECTRICAL POWER DISTRIBUTION BOX RELAY COVER REMOVAL/INSTALLATION
9.10.1. Description
This task covers:
Removal. Cleaning. Inspection. Installation.
9.10.2. Initial Setup
Tools:
Aircraft mechanics tool kit (item 376, App H)
Light duty laboratory apron (item 27, App H)
Chemical protective gloves (item 154, App H)
Industrial goggles (item 156, App H)
1 1/4-inch blade putty knife (item 199, App H)
Adjustable air filtering respirator (item 262, App H)
Materials/Parts:
Gasket (table D-73 or figure D-52, App D)
Adhesive (item 18, App F)
Brush (item 34, App F)
Strap (item 191, App F)
Personnel Required:
67R
Attack Helicopter Repairer
67R3F
Attack Helicopter Repairer/Technical
Inspector
References:
TM 1-1520-238-T
TM 55-1500-323-24
Equipment Conditions:
Ref
Condition
1.57
Helicopter safed
9.10.3. Removal
a. Enter pilot station (para 1.56). Observe all
safety precautions.
b. On pilot aft circuit breaker panel, open AFT
FAN circuit breaker.
GO TO NEXT PAGE
M04-4195-1
M04-4195-2