TM 1-1520-238-23
9-63
9.17.
GENERATOR CONTROL UNIT (GCU) FIXED CAPACITOR REPLACEMENT (AVIM) continued
f. Secure sleeving on lead (2) of capacitor C23
(3).
(1) Slide sleeving (4) over solder termination and
secure with lacing tape. Use insulation
sleeving (item 102, App F) and tape
(item 202, App F).
g. Oven cure 1 HOUR at 167 F (75 C). Use oven.
h. Inspect (QA).
i. Install generator control unit (GCU) circuit
card (para 9.16).
END OF TASK
M04-3705-9
1
4
3
2