TM 1-1520-238-23
9-65
9.18.
GENERATOR CONTACTOR RELAY NO. 1 OR NO. 2 REMOVAL/INSTALLATION continued
c. Detach connector P5 (4) from No. 1 contactor
relay (5) or connector P11 (4) from No. 2 con-
tactor relay (5).
(1) Detach connector P5 (4) from receptacle
(K1)J1 (6) or connector P11 (4) from recep-
tacle (K2)J1 (6).
d. Remove upper terminal shield (7) from relay
(5).
(1) Loosen two captive screws (8).
(2) Remove shield (7).
e. Detach wires (9) from terminal studs A2, B2,
and C2 (10).
(1) Identify wires (9).
(2) Remove three nuts (11), lockwashers (12),
flat washers (13), and seven terminal lugs
(14) from terminal studs (10).
f. Remove lower terminal shield (15) from relay
(5).
GO TO NEXT PAGE
M04-1103-4
`
7
8
5
4
6
M04-1103-5
9
14 13 12 11
5
10
M04-1103-6
15
5