TM 1-1520-238-23
9-412
9.112.
PILOT CAUTION/WARNING PANEL FIXED WIRE RESISTOR R1 REPLACEMENT
(AVIM) continued
9.112.6. Installation
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
a. Install (A106)R1 resistor (1) on housing (2).
(1) Position new resistor (1) on housing (2)
(TM 55-1500-323-24).
(2) Install two screws (4) through housing (2) and
resistor (1) flanges.
(3) Install two nuts (5) and lockwashers (6) on
screws (4).
(4) Solder identified wires (3) to resistor (4). Use
soldering iron and solder (item 189, App F)
(TM 55-1500-323-24).
b. Inspect (QA).
c. Install pilot caution/warning panel circuit
cards A1, A2, A3, and A4 (para 9.109).
d. Perform appropriate test. Electronic Equipment
Test Facility (E.E.T.F.) (TM 11-6625-3085-30).
END OF TASK
3
5
2
1
6
4
M04-4219-3