TM 1-1520-238-23
9-411
9.112.
PILOT CAUTION/WARNING PANEL FIXED WIRE RESISTOR R1 REPLACEMENT
(AVIM) continued
9.112.4. Cleaning
a. Clean fixed wire resistor mounting area on pilot caution/warning panel housing. Use isopropyl alcohol
(item 106, App F), brush (item 34, App F), and cloth (item 52, App F).
9.112.5. Inspection
NOTE
Unless otherwise specified, the following inspection procedures apply to the fixed wire resistor mount-
ing area on pilot caution warning panel housing.
a. Check for cracks. None allowed.
b. Check removed and attaching parts for damage (para 9.104).
c. Check removed and attaching parts for corrosion (para 1.49).
d. Check adjacent components for security of attachment and loose mounting (para 9.104).
e. Check adjacent wiring and wire bundles for cracked, broken, or burned insulation (para 9.104).
f. Check adjacent wiring and wire bundles for missing or broken tie wraps, chafing, wear, cuts, and
breaks (para 9.104).
g. Check for deposits of dust or foreign matter anywhere inside pilot caution/warning panel housing. None
allowed.
GO TO NEXT PAGE