TM 1-1520-238-23
9-445
9.119.
CPG CAUTION/WARNING PANEL FIXED CAPACITOR C3 OR C4 REPLACEMENT
(AVIM)
9.119.1. Description
This task covers:
Removal. Cleaning. Inspection. Installation.
9.119.2. Initial Setup
Tools:
Electronic equipment maintenance kit (item 208,
App H)
Light duty laboratory apron (item 27, App H)
Adjustable air filtering respirator (item 262, App H)
25-watt electric soldering iron (item 332, App H)
Materials/Parts:
Brush (item 34, App F)
Cloth (item 52, App F)
Insulating sleeving (item 98, App F)
Isopropyl alcohol (item 106, App F)
Solder (item 189, App F)
Personnel Required:
39B
ATE Operator/Maintainer
68X
Armament/Electrical System Repairer
68X3F
Armament/Electrical System Repairer/
Technical Inspector
References:
TM 11-6625-3085-30
TM 55-1500-323-24
Equipment Conditions:
Ref
Condition
9.115
CPG caution/warning panel circuit cards A1,
A2, A3, A4, and A5 removed
CAUTION
To prevent damage to pilot caution/warning panel, handle unit with care and ensure that work area is
clean and that parts are placed on a soft and adequately protected working surface.
To prevent electrostatic damage to other internal components of CPG caution/warning panel, ensure
that fixed capacitors are removed only on a static-free work station.
NOTE
This task is typical for capacitors (A157)C3 and (A157)C4 installed on top of pilot caution/warning
component bracket.
GO TO NEXT PAGE