TM 1-1520-238-23
9-451
9.120.
CPG CAUTION/WARNING PANEL CERAMIC FIXED CAPACITOR C5 REPLACEMENT
(AVIM) continued
9.120.4. Inspection
a. Check for cracks. None allowed.
b. Check removed and attaching parts for damage (para 9.104).
c. Check wires and terminals for wear, cracks, and cuts (para 9.104).
d. Check removed and attaching parts for corrosion (para 1.49).
e. Check for distortion and deformation (para 9.104).
f. Check for security of attachment and loose mounting (para 9.104).
g. Check adjacent capacitors for visible damage (para 9.104).
h. Check adjacent wiring and wire bundles for cracked, broken, or burned insulation (para 9.104).
i. Check adjacent wiring and wire bundles for missing or broken tie wraps, chafing, wear, cuts, and
breaks (para 9.104).
j. Check for deposits of dust or foreign matter anywhere inside CPG caution/warning panel housing. None
allowed.
GO TO NEXT PAGE