TM 1-1520-238-23
9-448
9.119.
CPG CAUTION/WARNING PANEL FIXED CAPACITOR C3 OR C4 REPLACEMENT
(AVIM) continued
9.119.6. Installation
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
CAUTION
Ensure that capacitor polarity is not re-
versed during installation. Accidental po-
larity reversal will damage capacitor and/or
other internal components of pilot caution/
warning panel.
a. Install capacitor (1) in clip (2).
(1) Install new sleeves (5) on leads (3). Use
insulating
sleeving
(item 98,
App F)
(TM 55-1500-323-24).
(2) Position capacitor (1) in clip (2) and secure
leads (3) to posts (4) (TM 55-1500-323-24).
(3) Solder identified leads (3) to posts (4). Use
soldering iron and solder (item 189, App F)
(TM 55-1500-323-24).
b. Inspect (QA).
c. Install CPG caution/warning panel circuit
cards (A157)A1, (A157)A2, (A157)A3,
(A157)A4, and (A157)A5 (para 9.115).
d. Perform appropriate test. Electronic Equipment
Test Facility (E.E.T.F.) (TM 11-6625-3085-30).
END OF TASK
M04-4224-3
5
1
2
3
4