TM 1-1520-238-23
9-450
9.120.
CPG CAUTION/WARNING PANEL CERAMIC FIXED CAPACITOR C5 REPLACEMENT
(AVIM) continued
WARNING
Discharge all capacitors by ground-
ing prior to removal. Capacitors can
hold an electrical charge and create a
dangerous potential for electrical
shock. If injury occurs, seek medical
aid.
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
Do not place heater near flammable
material or allow heater to contact
skin: severe burns can result. Wear
protective equipment. If injury
occurs, seek medical aid.
a. Remove capacitor C5 (1) from component
bracket (2).
(1) Identify and desolder capacitor leads (3) from
posts
(4).
Use
soldering
iron
(TM 55-1500-323-24).
(2) Remove and discard capacitor (1). Use putty
knife and heater to loosen adhesive.
9.120.3. Cleaning
a. Remove old adhesive from capacitor mount-
ing area. Use isopropyl alcohol (item 106, App F)
and cloth (item 52, App F).