TM 1-1520-238-23
9-447
9.119.
CPG CAUTION/WARNING PANEL FIXED CAPACITOR C3 OR C4 REPLACEMENT
(AVIM) continued
9.119.4. Cleaning
a. Clean bracket clip and soldering posts on component bracket. Use isopropyl alcohol (item 106, App F),
brush (item 34, App F), and cloth (item 52, App F).
9.119.5. Inspection
a. Check for cracks. None allowed.
b. Check removed and attaching parts for damage (para 9.104).
c. Check wires and terminals for wear, cracks, and cuts (para 9.104).
d. Check removed and attaching parts for corrosion (para 1.49).
e. Check for sharp bends, distortion, and deformation (para 9.104).
f. Check for security of attachment and loose mounting (para 9.104).
g. Check adjacent capacitors for visible damage (para 9.104).
h. Check adjacent wiring and wire bundles for cracked, broken, or burned insulation (para 9.104).
i. Check adjacent wiring and wire bundles for missing or broken tie wraps, chafing, wear, cuts, and
breaks (para 9.104).
j. Check for deposits of dust or foreign matter anywhere inside pilot caution/warning panel housing. None
allowed.
GO TO NEXT PAGE