TM 1-1520-238-23
9-449
9.120.
CPG CAUTION/WARNING PANEL CERAMIC FIXED CAPACITOR C5 REPLACEMENT
(AVIM)
9.120.1. Description
This task covers:
Removal. Cleaning. Inspection. Installation.
9.120.2. Initial Setup
Tools:
Electronic equipment maintenance kit (item 208,
App H)
Light duty laboratory apron (item 27, App H)
Electric gun type heater (item 163, App H)
1 1/4-inch blade putty knife (item 199, App H)
Adjustable air filtering respirator (item 262, App H)
25-watt electric soldering iron (item 332, App H)
Materials/Parts:
Adhesive (item 8, App F)
Brush (item 34, App F)
Cloth (item 52, App F)
Isopropyl alcohol (item 106, App F)
Solder (item 189, App F)
Personnel Required:
39B
ATE Operator/Maintainer
68X
Armament/Electrical System Repairer
68X3F
Armament/Electrical System Repairer/
Technical Inspector
References:
TM 11-6625-3085-30
TM 55-1500-323-24
Equipment Conditions:
Ref
Condition
9.116
CPG caution/warning panel bottom access
cover removed
CAUTION
To prevent damage to pilot caution/warn-
ing panel, handle unit with care and en-
sure that work area is clean and that
parts are placed on a soft and adequate-
ly protected working surface.
To prevent electrostatic damage to
other internal components of CPG
caution/warning panel, ensure ceramic
fixed capacitor is removed only on a stat-
icfree work station.
GO TO NEXT PAGE
C5
M04-4225-1