TM 1-1520-238-239-5189.136.MASS TERMINATION CONNECTOR (MTC) WITH SHIELD BUS (1 OR 2 INCH) REPAIR – continuedd. When working on harness installed in aircraft,attach static ground bus (11) to wafer (6). Verygentle insertion is sufficient for static grounding.NOTEWafers are identified as A or B to corre-spond to A or B side of connector. Con-tacts are 1 thru 10 (1.0 INCH) or 1 thru 20(2.0 INCH).e. Identify wire (12) to be removed from wafer (6).f. Make a shallow cut along length of wafersleeve (13) and bus sleeve (14) marked forremoval.Do not cut through sleeves (13) and(14).g. Install bus module (15) in repair fixture (16).h. Install wafer (6) in repair fixture (16).(1) Install wafer (6) with wafer key (17) face downunder clamping cover (18).(2) Bus (7) fits on alinement pins (19).i. Attach ground lead (20) to a reliable ground.GO TO NEXT PAGEM04-3066-3111661117151918161471213620M04-3066-32