TM 1-1520-238-23
9-515
9.135.
MASS TERMINATION CONNECTOR (MTC) (1 OR 2 INCH) REPAIR continued
9.135.7. Installation
a. Install wafers (6) and (7) in connector (1).
(1) Place wafers (6) and (7) together with wafer
keys (13) facing out.
(2) Aline A and B sides of wafers (6) and (7) with
A and B sides of connector (1).
(3) Insert wafers into connector until keys (13)
lock.
(4) Gently pull on wires (10) to ensure wafers (6)
and (7) are secure in connector (1).
b. Install two cable clamps (4) on connector (1).
(1) Tighten two captive screws (5).
c. Inspect (QA).
d. Attach connector (1) to connector (2).
(1) Tighten two captive jackscrews (3).
e. Perform
electrical
bond
check
(TM 55-1500-323-24).
(1) Bond shall be 0.0025 OHM or less. Use
ohmmeter.
f. Perform appropriate system maintenance op-
erational check (TM 1-1520-238-T).
END OF TASK
1
6
7
13
M04-3065-19
1
6
7
10
M04-3065-20
5
4
1
4
5
2
1
3
M04-3065-21
3