TM 1-1520-238-23
9-535
9.138.
COAXIAL MASS TERMINATION CONNECTOR (MTC) REPAIR continued
9.138.7. Installation
a. Insert contact (6) into connector (1).
(1) Slide cable (8) into insertion end of tool (7).
(2) Pull cable (8) until rear of contact (6) is flush
with tool (7).
(3) Push contact (6) and tool (7) into rear of con-
nector (1) until contact (6) clicks in place.
(4) Remove tool (7) from connector (1).
(5) Pull gently on cable (8) to ensure contact (6)
is fully seated.
b. Install two cable clamps (4) on connector (1).
(1) Position cable clamps (4) on connector (1).
(2) Install two screws (5).
c. Inspect (QA).
d. Attach connector (1) to receptacle (2).
(1) Tighten two captive screws (3).
e. Perform
electrical
bond
check
(TM 55-1500-323-24).
(1) Bond shall be 0.0025 OHM or less. Use
ohmmeter.
f. Perform appropriate system operational
check (TM 1-1520-238-T).
END OF TASK
M04-3067-12
7
1
8
M04-3067-13
7
6
1
8
M04-3067-14
4
1
5
3
2
1
3
M04-3067-15